  • Make sure that Survivability is set to Enabled (auto) on the Survivability page and that Request Subscriber Information from SIP Server is checked
  • On the Sip GW page make sure Enable SIP FXO/Line services is checked and Enable FXO port is checked for both port 1 and port 2
  • Finally on the VoIP Alg -> Sip -> Trunking page make sure there is an "Internal Sip Gateway" listed under the Sip Trunking Devices on the same network as the other VoIP devices and the Alg. Also make sure there is a Default Route routing all inbound calls to the Internal Gateway